Home | Sitemap Languages :   English   French   Germany   Dutch   Italian   Portuguese   Spanish  
CADD Services
Architectural Services
• 2D Drafting Services
• 3D Modeling Services
• Rendering Services
• Building Information Modeling (BIM)
• Animation & Walkthrough
Structural / Civil Services
• 2D Drafting & Detailing
• 3D Modeling Services
• Design Services
• Construction Documentation Services
Mechanical Services
• 2D Drafting Services
• 3D Modeling Services
• Mechanical Animation Services
Mechanical Electrical Plumbing
• HVAC Services
• Electrical Services
• Plumbing Services
Electrical Services
• 2D Drafting Services
• Design Services
Electronics Services
• Engineering Web Research
    Plumbing Services  

We specialize in preparing plumbing layout design and detailing, piping & plumbing shop / coordination drawings, piping construction drawings, material take-offs for various components etc.

A schematic representation of the workflow for Electrical & Plumbing services is depicted below:

Description

INPUT
  • Schematic Design Report
  • Applicable Code List
  • Design Guidelines or Standards
  • Symbols List (Titled Block)
  • Site Utility Plan
  • Architectural Layouts of Plumbing Fixture and Room Identity Number
  • Elevation of Building and Section Indication of Floor-To-Floor Height and Plenum Height
  • Size, Location, and Depth of all Adjacent Available Sewers, Water, and Gas Mains
  • Indicate any Special Requirement to the Local Department or Utility Company
  • The Available Maximum and Minimum Water Pressure at a Given Elevation, at Static and Residual Conditions
  • Minimum Pressure Required at Remote Fixture
  • Specify Whether Drinking Fountains Will Be Supplied From a Central Chilled Water System
  • Drinking Fountains should be provided with Local or Integral Cooling Units
  • Calorific Value of Fuel Gas
  • Minimum Pressure Required at Fixture and Available Gas Pressure
PROCESS

  • Reviewing location, type and giving identity (if not given) to plumbing fixture.
  • Documentation of the plumbing fixtures and size estimation of:
  • House sewers
  • Water services
  • Gas service
  • Hot water load
OUTPUT

Domestic Water System
  • Estimating friction loss per 100 ft from available pressure
  • Estimating distance of remote fixture and minimum pressure required for it
  • Determining the need of booster pumps for domestic water system
  • Assigning fixture unit to each plumbing fixture in accordance with usage and concerned codes
  • Finding total fixture units for hot and cold water
  • Converting fixture units to GPM (considering system predominant flash valve or flash tank)
  • Sizing all individual ranches in accordance with friction loss and flow requirement
  • Selecting and locating fittings like backflow preventors, water hammer arrestor, water pressure regulator etc.
Waste Water System
  • Assigning fixture unit to each plumbing fixture in accordance with usage and concern codes
  • Checking whether sump pumps or sewage ejector pumps are required
  • Determining the number of sanitary and vent risers considering space availability and obstruction
  • Sizing sanitary drainage / vent risers in accordance with the number of fixture units to be carried
  • Sizing horizontal of sanitary drainage / vent run in accordance with the number of fixture units to be carried and permissible slope from code
Storm Water System
  • Estimating roof area and finding riser and horizontal run size from rain flow data and applicable code
  • Locating roof drains, leaders, main stacks, fire standpipe risers, sprinkler risers, floor drains, floor sinks, funnel drains, etc. in according with the HVAC system
  • Verifying structural drawings for space conditions affecting the plumbing work with a special look out for beams below pipe chases
  • Providing necessary pipe spaces, wall thickness, etc for plumbing work
Riser Diagram for Domestic as well as Waste Water System
  • Domestic Hot / Cold Water Diagram.
  • Sanitary Drainage and Vent Diagram.
  • Storm Water Drainage Diagram.
  • Laboratory / Radioactive Drainage and Vent Diagram
  • Oral / Laboratory Vacuum Diagram
  • Fuel / Medical Gas Diagram,
  • Compressed Air Diagram,
  • Fire Protection Diagram
Typical Enlarge Diagram

Diagram showing details of plumbing accessories and connection to plumbing fixtures or pragmatically choose room.
  • Refining the design
  • Designing supports for pipe considering implication seismic zone if applicable
  • Indicating various type support at floor plan
  • Showing major pipe in double line
  • Organizing section for important location of floor plan
  • Coordinating with Electrical and HVAC services for location of pipe, drain etc (If necessary incorporate change in location)
  • Refining the drawing that shows all details required for execution of site work
Our Companies
 
           
           
 